--- title: "Gas Fired Series - Alkota Pressure Washers - Find Your Local Alkota Dealer" canonicalUrl: "https://alkota.com/products/hot-water-pressure-washers/gas-fired-hot-water-pressure-washer/" excerpt: "LP and Natural Gas Hot Water Pressure Washers Gas Fired Series Gas(LP and NG) Electric Motorw/ Belt Drive Stationary NEW: Approved for UL-60335-1, UL60335-2-79, CSA 522.2#60335 and E60335-2-79 Standards. Our stationary LP or natural gas pressure washers guarantee performance, durability, and serviceability. These cabinet-style units are available in a range of options, from 2-10 GPM and 1100-5000 PSI, providing the flexibility to meet your specific cleaning needs. Choose from 20 different models, and customize to your requirements. Features: Cabinet-style design ideal for stationary use, allowing easy installation and connection to remote cleaning stations using piping/hoses Water temperatures between 180 – 200 […]" metaDescription: "Stationary gas fired hot water pressure washers or cabinet style pressure washer are perfect for wash bays, and industrial settings." datePublished: "2023-12-04T21:08:22-05:00" dateModified: "2026-07-17T01:19:25-04:00" --- - Gas Fired Series - Alkota Pressure Washers - Find Your Local Alkota Dealer ** [Home](https://alkota.com/) > [Products](https://alkota.com/products/) > [Hot Water Pressure Washers](https://alkota.com/products/hot-water-pressure-washers/) > Gas Fired Series # LP and Natural Gas Hot Water Pressure Washers Gas Fired Series * ### Gas (LP and NG) ### Electric Motor w/ Belt Drive ### Stationary NEW: Approved for UL-60335-1, UL60335-2-79, CSA 522.2#60335 and E60335-2-79 Standards.** Our stationary LP or natural gas pressure washers guarantee performance, durability, and serviceability. These cabinet-style units are available in a range of options, from 2-10 GPM and 1100-5000 PSI, providing the flexibility to meet your specific cleaning needs. Choose from 20 different models, and customize to your requirements. **Features:** Cabinet-style design ideal for stationary use, allowing easy installation and connection to remote cleaning stations using piping/hoses - Water temperatures between 180 – 200 degrees Fahrenheit - Hydro-insulated coil enhances user safety and delivers cost-saving performance - 7-year coil warranty - Soft Damping System protects the coil, pump, and high-pressure component - UL & CSA certification ensures quality and compliance with essential safety standards **Included Accessories:** - Industrial hose with a swivel end and bend restrictor - Professional-grade insulated trigger gun with safety lock - Insulated wand for user safety - Quick connect nozzle - Winterizing valve to safeguard your investment against freezing Contact Alkota and we’ll put you in touch with a capable local dealer to help you find the perfect solution for your pressure cleaning needs. Upgrade your cleaning operations with reliable gas-fired hot water pressure washers by Alkota. ## FIND YOUR MODEL - Gas Fired Series **GPM** = Gallons Per Minute or Flow     **PSI** =  Pressure Per Square Inch     **V** = Volt     **PH** = Phase     **A** = AMP 4301*4 GPM / 3000 PSI 230v / 1PH / 40A *4201*3.6 GPM / 2000 PSI 230v / 1PH / 30A *5301*5 GPM / 3000 PSI 230v / 1PH / 50A *8351*8 GPM / 3500 PSI 230v / 3PH / 50A *10301*10 GPM / 3000 PSI 230v / 3PH / 50A NOT SURE? ## 4301 Specifications [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) Flow Rate4 gpmPressure3000 psiSteam Capacity120 gal/hourMotor Voltage230 vPhase1Amp Requirement40 ampMotor Power8 hpFuel SourceLP or NGGas ConsumptionLP: 3.8 gal/h or NG: 305 ft³/hBTU Rating365000 BtuPump StyleOil Bath Crankcase | Triplex Ceramic PlungerCoil TypeVertical Schedule 80Coil Construction TypeHydro insulated cold water wrap Coil Length243 ftCoil Pipe Diameter1/2 inFloat TankStandardFloat Tank Construction MaterialStainless SteelOptional Parts/FeaturesTemperature ControlChemical FeaturesHigh Pressure | Precise MeteredManufacturing NotesMotor/Voltage: Special voltages on request. Also available as oil fired modelExhaust Stack12 inLength56 inWidth27 inHeight55 inWeight810 lbs ## 4201 Specifications [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) Flow Rate3.6 gpmPressure2000 psiSteam Capacity90 gal/hourMotor Voltage230 vPhase1Amp Requirement30 ampMotor Power5 hpFuel SourceLP or NGNatural Gas ConsumptionLP: 3.5 gal/h or NG: 305 ft³/hBTU Rating365000 BtuPump StyleOil Bath Crankcase | Triplex Ceramic PlungerCoil TypeVertical Schedule 80Coil Construction TypeHydro insulated cold water wrap Coil Length168 ftCoil Pipe Diameter1/2 inFloat TankStandardFloat Tank Construction MaterialStainless SteelOptional Parts/FeaturesTemperature ControlChemical FeaturesHigh Pressure|Precise MeteredManufacturing NotesMotor/Voltage: Special voltages on request. Also available as oil fired modelExhaust Stack10 inLength56 inWidth27 inHeight55 inWeight615 lbs ## 5301 Specifications [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) Flow Rate5 gpmPressure3000 psiSteam Capacity150 gal/hourMotor Voltage230 vPhase1Amp Requirement50 ampMotor Power10 hpFuel SourceLP or NGGas ConsumptionLP: 5.4 gal/h or NG: 420 ft³/hBTU Rating440000 BtuPump StyleOil Bath Crankcase | Triplex Ceramic PlungerCoil TypeVertical Schedule 80Coil Construction TypeHydro insulated cold water wrap Coil Length243 ftCoil Pipe Diameter1/2 inFloat TankStandardFloat Tank Construction MaterialStainless SteelOptional Parts/FeaturesTemperature ControlChemical FeaturesHigh Pressure | Precise MeteredManufacturing NotesMotor/Voltage: Special voltages on request. Also available as oil fired modelExhaust Stack12 inLength56 inWidth27 inHeight55 inWeight880 lbs ## 8351 Specifications [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) Flow Rate8 gpmPressure3500 psiSteam Capacity240 gal/hourMotor Voltage230 vPhase3Amp Requirement50 ampMotor Power20 hpFuel SourceLP or NGGas ConsumptionLP: 7.25 gal/h or NG: 630 ft³/hBTU Rating660000 BtuPump StyleOil Bath Crankcase | Triplex Ceramic PlungerCoil TypeVertical Schedule 80Coil Construction TypeHydro insulated cold water wrap Coil Length399 ftCoil Pipe Diameter3/4 inFloat TankStandardFloat Tank Construction MaterialStainless SteelOptional Parts/FeaturesTemperature ControlChemical FeaturesHigh Pressure|Precise MeteredManufacturing NotesMotor/Voltage: Special voltages on request. Also available as oil fired modelExhaust Stack12 inLength70 inWidth33 inHeight65 inWeight1410 lbs ## 10301 Specifications [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) Flow Rate10 gpmPressure3000 psiSteam Capacity270 gal/hourMotor Voltage230 vPhase3Amp Requirement50 ampMotor Power20 hpFuel SourceLP or NGGas ConsumptionLP: 7.25 gal/h or NG: 840 ft³/hBTU Rating880000 BtuPump StyleOil Bath Crankcase | Triplex Ceramic PlungerCoil TypeVertical Schedule 80Coil Construction TypeHydro insulated cold water wrap Coil Length483 ftCoil Pipe Diameter3/4 inFloat TankStandardFloat Tank Construction MaterialStainless SteelOptional Parts/FeaturesTemperature ControlChemical FeaturesHigh Pressure|Precise MeteredManufacturing NotesMotor/Voltage: Special voltages on request. Also available as oil fired modelExhaust Stack12 inLength71 inWidth33 inHeight70 inWeight1710 lbs ## We're Here To Help If you’re having trouble deciding what Alkota will work best for your needs, rest assured, we’re here to help! You can view additional models, find a local distributor, or drop us a line. We are looking forward to hearing from you! [View ALL Gas Fired SERIES](https://alkota.com/shop/hot-water-pressure-washers/?cat=173) [Find A Local Distributor](https://alkota.com/distributors/) [Contact Alkota Cleaning Systems](https://alkota.com/contact/) ## SERIES HIGHLIGHTS Cabinet-style design Hydro-insulated coil enhances user safety and delivers cost-saving performance Coil with 7 year warranty * Water temperatures between 180 – 200 degrees Fahrenheit Stainless Steel Float Tanks Soft Damping System [Find a distributor](https://alkota.com/distributors/) [View Brochure](https://alkota.com/wp-content/uploads/2024/05/Gas-Fired-Series_5_25.pdf) [Request a Quote](#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjkxOCIsInRvZ2dsZSI6ZmFsc2V9) [*](javascript:void(0);) ## Request a Quote Complete the form below to request a quote. Search